Dry Power Refrigeration Dryer

HomeCompressed Air Treatment Dryers

Refrigeration Air Dryers Dry Power

DryPower line belong to a class type with refrigerated dryers capacity range of 22 to 204 m3/min at a maximum pressure of 16 bar.Dry Power Refrigeration Dryer

Maximum temperature of the incoming compressed air dryers is + 65°C, which is significantly higher than that provided by other manufacturers. The maximum index ambient temperature is + 430°C. High operating parameters of compressed air achieved by using a specially designed heat exchanger.

The principle of the dryer Dry Power

The process of drying compressed air to the cold dryer is due to the cooling of the air masses of compressed air. During the cooling of the water molecules lose kinetic energy, whereby the interaction between the molecules begins to dominate the chaotic traffic.

As a result - the water molecules form water droplets. When they reach a certain size, then under the attraction force of moisture deposited on the walls of the heat exchanger. This is called condensation. After the air heat exchanger is supplied to the separation, where the final separation and removal of moisture.

Dry Power technical features

ModelEfficiencyEnergy use
(kW)
LinkageDimensions (mm)Weight (kg)
m3/yearm3/minABC
MG 0221,32222,14DN 806601,231,4244
MG 0281,68283,35DN 806601,231,4254
MG 0372,22373,77DN 806601,231,4276
MG 0452,7455,05DN 1006601,231,4318
MG 0603,67607,09DN 1006601,231,4332
MG 0774,62778,12DN 1509101,791,447526
MG 0905,441909,69DN 1509101,791,447551
MG 1106,67511011,8DN 1509101,791,447624
MG 1509,03115015,3DN 2009302,862,0641,077
MG 19011,42119019,7DN 2009302,862,0641,102

The cooling circuit compressed air dryer

Dehumidifiers of compressed air lines Dry Power operate on a freon cooling. The heart of every refrigeration dryer is a freon compressor. The refrigeration circuit is applied capillary tube, so that there is no need for seasonal adjustments. The upper capacitor helps to reduce pollution.

The compressed vapors enter the condenser where the moisture settles. The capacitor can be air or water cooled. The air condenser is a plate heat exchanger that is cooled by air flow from the blower motor.

After the condenser, liquid refrigerant passes through the filter-drier into a capillary for further reduction of the pressure to the boiling point. The substance boils in the tubes of the evaporator, thereby cooling the compressed air. Then the refrigerant vapor absorbed by the compressor and the cycle repeats.

Why choose us?

..........

Unique product



40% savings



Stability



Trust



Individual approach









Official dealers of Sotras, Noitech, Filtrec


Exclusive partnerships with manufacturers give us the possibility to deliver the goods at the lowest prices


6 years of successful work, hundreds of satisfied clients and our own production

We do not have occasional customers - everyone becomes part of a team of leaders!


Individual approach for each client

 

  G Analytics
разработка сайта веб студия